SPA-1 High-Performance and Standard Probe
 
SPA-1
High-Performance
and Standard Probe
Test Center .75 (1.91)

Tips

Spring Force

Connectors

How to Order

   
 
Probe Specifications
Mechanical
Full Travel: .100 (2.54)
Recommended
Working Travel:
.067 (1.70)
Mechanical Life Exceeds: 1 x 106 cycles

Operating Temperature -55°C to +150°C
Consult factory for other temperature requirements, and applications below -40°

Electrical (Static Condition)
Current Rating: 3 amps
Maximum continuous current, non-inductive at working travel

Probe Resistance 50 milliohms
With a standard deviation of <7 milliohms @ 25 mA test current

Materials and Finishes
Plunger: Heat-treated beryllium copper, rhodium plated over hard nickel
Barrel: Work-hardened phosphor bronze, HPA-GOLD™ plated (I.D. and O.D.) over hard nickel
Spring: Stainless steel, silver plated
 
Receptacle Specifications
Mounting Hole Size: .053/.055 (1.35/1.40)
A #54 or 1.4 mm drill is most commonly used

Recommended
Wire Gauge:
24-28 AWG

Connections: SPR-1W Crimp

SPR-1W-1 Solder cup

SPR-1W-2/SPR-1W-2M Wire wrap/square post. Vacuum leak rate not to exceed 1 x 10-4 CFM @ 15 psi


Materials and Finishes
Housing: Work-hardened nickel silver, gold plated over hard nickel
Square Post: Phosphorous bronze, gold plated
The SPA-1 may be used to test bare PCBs on mixed test centers with the HPA-0 and HPA-74 probes.


Tips (top)



Spring Force (top)

Spring Force in 0z. (grams)
Spring Type   Preload 2/3 Travel
To order add dash number to Model Number
Standard Shown 1.1 (31) 2.5 (71)
Alternate -1 1.3 (37) 4.5 (128)
Optional spring forces and materials are available



Connectors (top)



How to Order (top)

For each probe, specify the probe model and tip style as shown in the example below. If required, specify the optional non-standard spring force.

Example:

Order Form

 

©1998-2003 Everett Charles Technologies. All rights reserved. Everett Charles Technologies, 700 E. Harrison Ave., Pomona, CA, 91767, U.S.A.